The so-called head refers to the required head, not the lifting height, and it is particularly important to clarify this when choosing a water pump. The head of the water pump is approximately 1.15-1.20 times the lifting height. If the vertical height from a water source to the water usage point is 20 meters, the required lift is approximately 23-24 meters.
When selecting a water pump, it is best to ensure that the head on the pump nameplate is close to the required head, with a general deviation of no more than 20%. In this case, the pump has the highest efficiency and is more energy-efficient, making it more economical to use. If the lift on the nameplate is much lower than the required lift, the water pump often cannot meet the user's needs, and even if it can pump water, the amount of water is pitifully small. But conversely, when a high head water pump is used for low head, there will be excessive flow, causing the motor to overload. If it runs for a long time, the temperature of the motor will rise, and the insulation layer of the winding will gradually age, even burning out the motor.
Introduce the requirements for the usage conditions of horizontal water pumps
Characteristics of horizontal water pump
The water pump produced by the factory is suitable for pumping and discharging sewage and sludge in various harsh environments. The water pump is a down suction type, capable of draining surface water from the working surface, and the electric motor is a water filled asynchronous three-phase stepper motor. Can work underwater for a long time or work above the water surface. Small footprint, easy installation and use, reliable and durable, with a long lifespan. Below are the conditions for using a horizontal water pump.
Service conditions for horizontal water pump
A horizontal water pump is a lifting device that is directly connected to a motor and a water pump and operates underwater. Mainly suitable for irrigation of farmland, urban areas, and water supply and drainage projects in industrial and mining enterprises.
Power requirements for the use of horizontal water pumps:
1. The rated frequency is 50 Hz, and the rated voltage at the motor end should be ensured to be 380 ± 5% of a three-phase AC power supply (if the user's voltage is 660 volts, special orders are required)
2. The load power of the transformer should not exceed 75% of its capacity.
When the transformer is far away from the well, the voltage drop of the transmission line should be considered. For motors with a power greater than 45KW, the distance from the transformer to the wellhead should not exceed 20 meters. When it is greater than 20 meters, the transmission line specification should be two levels larger than the cable specification, and the voltage drop of the line should be considered.
Water quality requirements for horizontal water pumps:
1. Generally non corrosive clean water
2. The sand content in the water shall not exceed 0.01% (by mass)
3. The pH value is within the range of 6.5-8.5.
4. The chloride ion content in water shall not exceed 400 milligrams per liter
5. Hydrogen sulfide content not exceeding 1.5 milliliters per liter
6. The water temperature should not exceed 20 ℃.
Summary of the operating environment and conditions of horizontal water pumps:
1. A three-phase AC power supply with a power frequency of 50Hz and a rated voltage of 380V or 660V (with a charge tolerance of plus or minus 5%).
2. The volume ratio of solid material in the conveying medium is below 2%, and the density of the conveying medium is 1.2 x 10.
3. The temperature of the conveying medium shall not exceed 40 degrees.
4. The pH value of the conveying medium is 4-10.
5. The sewage submersible pump unit without a cover is allowed to operate for no more than 0.5 hours with the electric pump motor exposed to the water surface from the cooling state of the motor.
6. Based on the center of the impeller, the depth of penetration shall not exceed 20m.