Unable to start
Firstly, the power supply situation should be checked: whether the connector connection is secure; Is the switch contact tight; Is the fuse blown; Whether the three-phase power supply is equal or not. If there is a circuit break, poor contact, blown fuse, or phase loss, the cause should be identified and repaired in a timely manner. Next, check if it is a mechanical failure of the water pump itself. Common causes include: too tight packing or blockage between the impeller and the pump body due to debris; The pump shaft, bearings, and leakage reducing ring are rusted; The pump shaft is severely bent, etc. Exclusion method: Loosen the filling material and unclog the drainage channel; Disassemble the pump body to remove debris and rust; Remove the pump shaft for calibration or replace it with a new pump shaft.
The water pump is heating up
Reason: Bearing damage; The clearance between rolling bearings or bracket covers is too small; The pump shaft is bent or the two shafts are not concentric; The tape is too tight; Lack of oil or poor oil quality; The balance hole on the impeller is blocked, causing the impeller to lose balance and increase the thrust to one side. Exclusion method: Replace the bearing; Remove the back cover and install a gasket between the bracket and the bearing seat; Investigate the pump shaft or adjust the concentricity of the two shafts; Adjust the tightness of the tape appropriately; Add clean butter, which accounts for about 60% of the clearance inside the bearing; Clear the blockage in the balance hole.
Unable to suck water
The reason is that there is air inside the pump body or air accumulation in the inlet pipe, or the bottom valve is not tightly closed and the water supply is not sufficient, the vacuum pump packing is severely leaking, and the gate valve or flap valve is not tightly closed. Exclusion method: First, increase the water pressure, then fill the pump body with water, and then turn it on. At the same time, check whether the check valve is tight and whether there is any air leakage in the pipeline and joints. If any air leakage is found, apply lubricating oil or blending paint to the joint after disassembly, and tighten the screws. Check the oil seal ring of the water pump shaft, and replace it with a new one if it is severely worn. Pipeline leakage or air leakage. The nut may not be tightened during installation. If the leakage is not severe, cement can be applied to the leaking or leaking area, or cement slurry mixed with asphalt oil can be applied. Temporary repairs can be done by applying some wet mud or soft soap. If there is water leakage at the joint, a wrench can be used to tighten the nut. If the water leakage is severe, it must be disassembled and replaced with a cracked pipe; Reduce the head and press the pipe mouth of the water pump 0.5m underwater.
Summary
There are several main reasons: unbalanced electric rotor; Poor coupling connection; Bearing wear and bending; Loose or broken parts of the rotating parts; Reasons such as unstable pipeline supports. Measures such as adjustment, repair, reinforcement, straightening, and replacement can be taken to handle it separately.