Analysis of the causes of water pump vibration

There are many reasons for the vibration of the unit and pump room buildings caused by the analysis of the causes of water pump vibration. Some factors are both related and interact with each other. In summary, there are four main reasons.


Electrical aspect
The motor is the main equipment of the unit, and the magnetic imbalance inside the motor and the imbalance of other electrical systems often cause vibration and noise. During the operation of asynchronous motors, the radial alternating magnetic pulling force between the stator and rotor generated by the interaction of harmonic magnetic flux between the stator and rotor teeth, or during the operation of large synchronous motors, the magnetic center of the stator and rotor is not consistent or the air gap difference in all directions exceeds the allowable deviation value, may cause periodic vibration and noise of the motor.


Mechanical aspects
Unequal quality, rough manufacturing, poor installation quality, asymmetric unit axis, excessive swing, poor mechanical strength and stiffness of components, wear and damage of bearings and sealing components, as well as resonance between the critical speed of the water pump and the natural frequency of the unit, can all produce strong vibrations and noise.


Hydraulic aspect
Uneven flow velocity and pressure distribution at the inlet and outlet of the water pump, pressure pulsation, liquid flow, deviation and detachment of the working fluid at the inlet and outlet of the pump, non rated operating conditions, and cavitation caused by various reasons are common causes of pump unit vibration. The sudden changes in pressure and water hammer in the water pipeline caused by dynamic transition processes such as pump start-up and shutdown, valve opening and closing, changes in operating conditions, and emergency shutdown in accidents often lead to vibration in the pump room and units.

Send Inquiry

Home

Phone

E-mail

Inquiry